ㆍ홈 > ISAR/RCS/UWB 신호측정 > ISAR/RCS 측정시스템  

  ISAR & RCS 측정 시스템                                                                              

엘텍에서는 Ultra Wide Band 신호 계측 솔루션 전문 제조 업체인  Geozondas 사와 국내 총판 계약을 체결 하여
역합성개구면(ISAR) 레이더 이미지 측정 시스템을 국내에 공급 합니다.

  Geozondas 사의 제품은 아래와 같습니다.
Traditionally RCS measurements are carried out in Frequency Domain. Usage of short impulses as test signals enables to do RCS measurements in wide frequency band. ISAR Imaging is RCS density plot

Traditionally RCS measurements are carried out in Frequency Domain. Usage of short impulses as test signals enables to do RCS measurements in wide frequency band. ISAR Imaging is RCS density plot. ISAR Imaging is used for measurement and modeling the properties of different scattered targets. High resolution images can be achieved using Time Domain measurements. Time Domain method allows to obtain substantial advantages:
• Using time windowing it is easy to exclude signal from occasional reflections from the walls, ceilings and from signal leakage in bistatic and monostatic measurements.
• Possibility to acquire measurement signals that are asynchronous with interference from GSM base stations, Radio and TV transmitters and etc. All advantages enable to carry out measurements without anechoic chamber. Time Domain Measurement System includes Pulse Generator (30 ps duration), Sampling Converter (DC-26 GHz), Positionier, Transmitting and Receiving antennas, Personal Computer. Using pulse drift correction algorithms space resolution is achieved up to 1.5 mm. These results can be applied to non-destructive control, security, and biomedical imaging.
Slideshow (5 second delay):
ON / OFF Previous   Next 
Slideshow image
Airplane
RCS&2D ISAR Measurement System 3÷18 GHz

Name of parameter Value
Parameters under test (Far Field) Radar Cross Section
Frequency range 3÷18 GHz
Target size 2,5 cm < D < 30 cm
Distance between antennas and target Up to 5 m

Product Name
Time Domain Measurement System for RCS measurements and ISAR Imaging

System consist of ;
1. Set of Antennas: Transmitting GZ0126DRH, Receiving      GZ0126DRH

2. Digital Sampling Converter SD203TM
3. Sampling Unit SU3126 with Control Cable CSU31/15m
4. Pulse Generator Mainframe GZ1106DL2
5. Pulse Generator Head GZ1117DN-25
6. 1-Axis Positioner GZPU-1/10
Set of connective RF Cables, Phase Stable Sucoflex and adapters 