¸ÞÀκ»¹®
     

¤ýȨ > ±¤ ÀÀ¿ë °èÃø±â > FROG ·¹ÀÌÀúÆÞ½ºÃøÁ¤±â > PRODUCTS  

Ãʰí¼Ó ÆÞ½º ÃøÁ¤ ½Ã½ºÅÛ-FROG Scan Ultra

°¡°Ý 0
Àû¸³±Ý 0
¼ö·®

FROGscan Ultra ·¹ÀÌÀú ÆÞ½º ÃøÁ¤ ½Ã½ºÅÛ

¿ì¸®ÀÇ FROGscan Ultra ½Ã½ºÅÛÀº ÃÖ°íÀÇ °¡Ä¡¿Í ´Ù¾ç¼ºÀ» Á¦°øÇÕ´Ï´Ù. 

´ÜÀÏ FROGscan Ultra ÀåÄ¡´Â ³ÐÀº ÆÄÀå ¹üÀ§, ³ôÀº ½ºÆåÆ®·³ ºÐÇØ´É ¹× 75dB ÀÌ»óÀÇ µ¿Àû ¹üÀ§¸¦ Á¦°ø ÇÒ ¼öÀÖ´Â ´Ù¾çÇÑ ºÐ±¤°è¸¦ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. 450 nm¿¡¼­> 4000 nm±îÁöÀÇ ÆÄÀåÀº ´ÜÀÏ ½Ã½ºÅÛÀÇ ¹üÀ§ ³»¿¡ ÀÖ½À´Ï´Ù. Á¦·Î ºÐ»ê ¼³°è·Î 5fs ¹Ì¸¸ÀÇ ÆÞ½º¸¦ ÃøÁ¤ ÇÒ ¼ö ÀÖ½À´Ï´Ù. Ç¥Áذú ¸¶Âù°¡Áö·Î Ultra´Â ¸Å¿ì º¹ÀâÇÑ ÆÞ½º¸¦ ½±°Ô ÃøÁ¤ÇÕ´Ï´Ù.



FROGscan Ultra´Â ÀÏÇÏ´Â ÆÞ½º ÃøÁ¤ ½Ã½ºÅÛÀÔ´Ï´Ù. 
¿ì¸®´Â ¸ðµç ÆÞ½º ÃøÁ¤ ¿ä±¸ »çÇ׿¡ ´ëÇØ ¸ÅÀÏ »ç¿ëÇϵµ·Ï ¼³°è ¹× Á¦ÀÛÇß½À´Ï´Ù.
·¹ÀÌÀú ½Ã½ºÅÛÀ» Á¶Á¤ÇÏµç ¼ºÇü µÈ ÆÞ½º¸¦ ÃøÁ¤Çϵç FROGscan Ultra´Â ÃÖ°íÀÇ ÆÞ½º ÃøÁ¤ ½Ã½ºÅÛÀÔ´Ï´Ù. »õ·Î¿î ÆÄÀåÀÌ ÇÊ¿äÇÏ¸é ¾î¶»°ÔµË´Ï±î? SHG Å©¸®½ºÅ»°ú ºÐ±¤°è¸¦ º¯°æÇÏ¿© Çʿ信 ¸Â°Ô Á¶Á¤Çϱ⠸¸ÇϸéµË´Ï´Ù. Å©¸®½ºÅ» º¯°æ¿¡´Â Àç¹èÄ¡°¡ ÇÊ¿äÇÏÁö ¾Ê½À´Ï´Ù. ¿îµ¿ ÇÐÀûÀ¸·Î ÀåÂøµÇ°í ¼ÒÇÁÆ®¿þ¾î°¡ Å©¸®½ºÅ» »ç¾çÀ» ÀнÀ´Ï´Ù. 3000nm ÆÞ½º ÃøÁ¤ÀÌ ÇÊ¿äÇϽʴϱî? AGS Å©¸®½ºÅ»°ú Ocean Insight NIR Quest ºÐ±¤±â¸¦ ³ÖÀ¸¸éµË´Ï´Ù. µ¿ÀÏÇÑ ½Ã½ºÅÛÀ¸·Î 450nm ÆÞ½º¸¦ ÃøÁ¤ ÇÒ ¼ö ÀÖ½À´Ï´Ù. AGS Å©¸®½ºÅ»À» BBO·Î ±³Ã¼ÇÏ°í ºÐ±¤°è¸¦ º¯°æÇϱ⠸¸ÇϸéµË´Ï´Ù. ¼ÒÇÁÆ®¿þ¾î ³ª º¸Á¤¿¡¼­ ¼³Á¤ÇÒ Çʿ䰡 ¾ø½À´Ï´Ù. ³ôÀº ½ºÆåÆ®·³ ÇØ»óµµ°¡ ÇÊ¿äÇϽʴϱî? HR2000 + ºÐ±¤±â¸¦ »ç¿ëÇϽʽÿÀ. ÃøÁ¤ÇؾßÇÏ´Â ÃÖ´Ü ÆÞ½º (<5fs ¶Ç´Â 10fs)¿¡ µû¶ó µÎ °¡Áö ´Ù¸¥ FROGscan Ultra ¸ðµ¨ Áß¿¡¼­ ¼±ÅÃÇϽʽÿÀ.

¿ì¸®ÀÇ FROGscan Ultra´Â À§ÀÇ »çÁøÀÔ´Ï´Ù. ·¹ÀÌÀú ºöÀº Á¤·Ä Á¶¸®°³¸¦ ÅëÇØ ¿À¸¥ÂÊ¿¡¼­ µé¾î¿É´Ï´Ù. Á¤·Ä Ä«¸Þ¶ó (¿É¼Ç)¸¦ »ç¿ëÇÏ¸é ½Ã½ºÅÛÀ» ½±°Ô Á¤·Ä ÇÒ ¼ö ÀÖ½À´Ï´Ù. ºö ½ºÇø®ÅÍ´Â °íÁ¤ µÈ Áö¿¬À» ÅëÇØ ÇϳªÀÇ ÆÞ½º º¹Á¦º»À» º¸³À´Ï´Ù. ´Ù¸¥ º¹Á¦º»Àº °í¼Ó, °íÁ¤¹Ð ±¤ÇÐ Áö¿¬ ¶óÀÎÀ¸·Î Àü¼ÛµË´Ï´Ù. µÎ ºö ¸ðµÎ 2 Â÷ °íÁ¶ÆÄ »ý¼º Å©¸®½ºÅ»¿¡ ÁýÁߵ˴ϴÙ. ÆÞ½º Áßø ¿µ¿ªÀÇ SHG ½ÅÈ£´Â Ocean Insight ºÐ±¤°è (HR2000 +, HR4000, Maya Pro, QE Pro, NIR Quest ¶Ç´Â µ¿ÀÏÇÑ Ç² ÇÁ¸°Æ®¸¦ °¡Áø ¸ðµç °Í)¸¦ »ç¿ëÇÏ¿© ½ºÆåÆ®·³À¸·Î ºÐ¼®µË´Ï´Ù. ¼ÒÇÁÆ®¿þ¾î´Â ºÐ±¤°è¿¡¼­ ºÐ±¤°è »ç¾çÀ» ÀнÀ´Ï´Ù. ÀÌ ¼ÒÇÁÆ®¿þ¾î´Â ÀÌÀü ºÐ±¤°è¿Í ¿ª ȣȯµË´Ï´Ù.

±×·¯³ª ´Ü¼øÇÔ¿¡ ¼ÓÁö ¸¶½Ê½Ã¿À. ½ºÄµ ½Ã°£ ¹üÀ§¸¦ ¿øÈ°ÇÏ°Ô º¯°æÇÒ ¼ö Àֱ⠶§¹®¿¡ FROGscanÀÇ ´ÜÀÏ ±¸¼ºÀ¸·Î 3 °³ ÀÌ»óÀÇ °æÀï FROG ÀåÄ¡¸¦ ´ëü ÇÒ ¼ö ÀÖ½À´Ï´Ù. 16 ºñÆ® µ¥ÀÌÅÍ ¼öÁýÀÇ Ãß°¡ µÈ µ¿Àû ¹üÀ§¸¦ ÅëÇØ °íµµ·Î ±¸Á¶È­ µÈ ÆÞ½º¿Í °íÂ÷ À§»ó ¿Ö°îÀ» ÃøÁ¤ ÇÒ ¼ö ÀÖ½À´Ï´Ù. Á¤·Ä Ä«¸Þ¶ó (¿É¼Ç)¸¦ »ç¿ëÇÏ¸é ½Ã½ºÅÛ ¼³Á¤À» ½±°Ô ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¿É¼Ç ¼ÒÇÁÆ®¿þ¾î Á¦¾î Å©¸®½ºÅ» ƿƮ´Â Á¶Á¤ °¡´ÉÇÑ ·¹ÀÌÀú ¼Ò½º·Î ÀÛ¾÷À» °£´ÜÇÏ°Ô ¸¸µì´Ï´Ù.

¿ì¸® ÀåÄ¡´Â °æÀï ÀåÄ¡°¡ ÇÒ ¼ö¾ø´Â ÃøÁ¤À» ¼öÇà ÇÒ ¼öµµ ÀÖ½À´Ï´Ù. ¿¹¸¦ µé¾î, °æÀï FROG ÀåÄ¡¸¦ »ç¿ëÇÏ¿© 10ps ÀÌ»óÀ¸·Î óÇÁ µÈ 10fs ·¹ÀÌÀú ÆÞ½º ¶Ç´Â 200fs ¸¸ ÃøÁ¤ ÇØº¸½Ê½Ã¿À. ´ç½ÅÀº ÇÒ ¼ö ¾ø½À´Ï´Ù. ÆÞ½º ±æÀÌ¿Í ´ë¿ªÆøÀÇ Á¶ÇÕÀº ºÐ»ê ¿ä¼Ò·Î SHG Å©¸®½ºÅ»À» »ç¿ëÇÏ´Â ÀåÄ¡¿¡¼­ ó¸® ÇÒ ¼ö ​​¾ø½À´Ï´Ù. FROGscanÀ» »ç¿ëÇϸé ÀÌ·¯ÇÑ ÃøÁ¤À» ½±°Ô ¼öÇà ÇÒ ¼ö ÀÖ½À´Ï´Ù. ½Ã°£ ½ºÄµ ¹üÀ§´Â ¼ÒÇÁÆ®¿þ¾î Á¦¾î¸¦ ÅëÇØ Áï½Ã º¯°æ µÉ ¼ö ÀÖÀ¸¸ç ÆÄÀåµµ º¯°æ µÉ ¼ö ÀÖ½À´Ï´Ù. ÄÄÇ»ÅÍ¿¡ ´ëÇÑ USB ¿¬°á ¸¸ ÀÖÀ¸¸éµË´Ï´Ù. ¼ÒÇÁÆ®¿þ¾î°¡ Æ÷ÇԵǾî Àֱ⠶§¹®¿¡ ÆÞ½º ÃøÁ¤¿¡ »ç¿ëÇÒ ¼öÀÖ´Â ÃÖ»óÀÇ °ªÀÔ´Ï´Ù.


FROGscan Ultra

Input Parameters
Input Beam Size > 2 mm, 10 mm clear aperture
Input polarization horizontal
Minimum Power (Average Power)2/(Rep rate X Pulse Width) > 4W2/pulse
Input Pulse Wavelength Range 450 nm – ~4000 nm, spectrometer and crystal dependent
Minimum Pulse width ~ 7 fs
Temporal Range ~10 ps (60 ps*)
Maximum Time Bandwidth product ~ 50
Data Acquisition
Patents US patent # 7,130,052, 8,068,230
Digitization Resolution 14 – 16 -bit (Spectrometer Dependent)
Minimum Delay Increment 1 fs
Spectrometer Spectral Resolution Minimum 0.04 nm
Spectrometer Spectral Resolution Typical 0.44 nm
Spectrometer Spectral Resolution Maximum ~ 1 nm
Spectral resolution at input wavelength (¡°effective spectral resolution¡±) ~2 x sqrt(2) x spectrometer resolution
Spectral Range Spectrometer Dependent and pulse width dependent, nominally 100 nm – 600 nm per spectrometer
Minimum Integration time (spectrometer dependent) 1 ms¢Ó
Repetition rate (without triggering) 100 Hz – > 1 GHz
Triggered repetition rate < 1 Hz – ~ 1 kHz¢Ô
Intensity Accuracy ~ 2%
Phase Accuracy 0.01 radians 0.01 radians
Spectra required for measurement Number in grid
Acquisition Speed ~130 spectra/second
Maximum Grid Size 1024 x 1024
Maximum Optical Delay acceleration 28G (19G*)
Maximum speed based on maximum acceleration 11.2 ns/s (1.68 m/s) (9.2 ns/s (1.38 m/s)*)
Optional Accessories
Software controlled crystal tilt
Direct Drive microstepped, 5 pole stepper motor Yes
Angular resolution < 0.1 degrees
Angular repeatability better than 0.1 degrees
Angular range +/- 30 degrees
Angular tilt scanning for increased phase mathcing bandwidth Yes
Alignment Cameras
Sensor silicon CCD cameras 2
Wavelength range 450 nm – 1000 nm(out to ~1550 nm using 2 photon absorption)
Focal plane of crystal image Yes
Fixed delay beam Yes
USB 2.0 Interface Yes
Frame rate 8-10 Hz
Physical
Dimensions 33 cm x 33 cm x 19 cm
Shipping weight about 40 lbs (18.2 kg)
Power requirements 100 – 230 VAC, 50 – 60 Hz
Electrical Plug style: US NEMA 5-15, change on request
Cover Integrated
Control electronics Integrated
Crystal mounting Removable/replaceable Kinematic Cartridge
Spectrometer Mount Kinematic Removable
Beam splitter Reflective, spatial
Data Analysis
Video FROGscan software Included
Algorithm speed 64 x 64 grid (Core i7, Gen. 7, mobile) > 12,600 iterations per second
Algorithm speed per pixel ~ 20 us
Algorithm type Proprietary PCPG (US patent # 6,219,142, 9,423,307, 10,274,378)
Analysis rate real-time
Update once per frame
Preprocessing background subtraction, smoothing, median filter, adaptive rank filter
Notes
*With the optional Hollow retroreflector
¢ÓMinimum integration time: Flame 1 ms; HR2000+ 1 ms; QEpro 8 ms; Maya Pro 7.2 ms; Ocean FX 10 ¥ìs.
¢Ô At greater than ~50-100 Hz, not every pulse is captured. E.g., pulses are skipped.

FROGscan Ultra – Short Pulse

Input Parameters
Input Beam Size > 2 mm, 10 mm clear aperture
Input polarization horizontal
Minimum Power (Average Power)2/(Rep rate X Pulse Width) > 4W2/pulse
Input Pulse Wavelength Range 450 nm – 2000 nm, spectrometer and crystal dependent
Minimum Pulse width < 5fs
Temporal Range ~10 ps (60 ps*)
Maximum Time Bandwidth product ~ 50
Data Acquisition
Patents US patent # 7,130,052, 8,068,230
Digitization Resolution 16 -bit
Minimum Delay Increment 1 fs
Spectrometer Spectral Resolution Minimum 0.2 nm
Spectrometer Spectral Resolution Typical 0.44 nm
Spectrometer Spectral Resolution Maximum 1.4 nm
Spectral resolution at input wavelength (¡°effective spectral resolution¡±) ~2 x sqrt(2) x spectrometer resolution
Spectral Range Spectrometer Dependent and pulse width dependent, nominally 100 nm – 600 nm per spectrometer
Minimum Integration time (spectrometer dependent) 10 ¥ìs (using Ocean FX spectrometer)¢Ó
Repetition rate (without triggering) 100 Hz – > 1 GHz
Triggered repetition rate < 1 Hz – ~ 1 kHz¢Ô
Intensity Accuracy ~ 2%
Phase Accuracy 0.01 radians 0.01 radians
Spectra required for measurement Number in grid
Acquisition Speed ~130 spectra/second
Maximum Grid Size 1024 x 1024
Maximum Optical Delay acceleration 28G (19G*)
Maximum speed based on maximum acceleration 11.2 ns/s (1.68 m/s) (9.2 ns/s (1.38 m/s)*)
Optional Accessories
Software controlled crystal tilt
Direct Drive microstepped, 5 pole stepper motor Yes
Angular resolution < 0.1 degrees
Angular repeatability better than 0.1 degrees
Angular range +/- 30 degrees
Angular tilt scanning for increased phase mathcing bandwidth Yes
Alignment Cameras
Sensor silicon CCD cameras 2
Wavelength range 450 nm – 1000 nm(out to ~1550 nm using 2 photon absorption)
Focal plane of crystal image Yes
Fixed delay beam Yes
USB 2.0 Interface Yes
Frame rate 8-10 Hz
Physical
Dimensions 33 cm x 33 cm x 19 cm
Shipping weight about 40 lbs (18.2 kg)
Power requirements 100 – 230 VAC, 50 – 60 Hz
Electrical Plug style: US NEMA 5-15, change on request
Cover Integrated
Control electronics Integrated
Crystal mounting Removable/replaceable Kinematic Cartridge
Spectrometer Mount Kinematic Removable
Beam splitter Reflective, spatial
Data Analysis
Video FROGscan software Included
Algorithm speed 64 x 64 grid (Core i7, Gen. 7, mobile) > 12,600 iterations per second
Algorithm speed per pixel ~ 20 us
Algorithm type Proprietary PCPG (US patent # 6,219,142, 9,423,307, 10,274,378)
Analysis rate real-time
Update once per frame
Preprocessing background subtraction, smoothing, median filter, adaptive rank filter
Notes
*With the optional Hollow retroreflector
¢ÓMinimum integration time: Flame 1 ms; HR2000+ 1 ms; QEpro 8 ms; Maya Pro 7.2 ms; Ocean FX 10 ¥ìs.
¢Ô At greater than ~50-100 Hz, not every pulse is captured. E.g., pulses are skipped.

FROGscan Ultra – Long Pulse

Input Parameters
Input Beam Size > 2 mm, 8 mm clear aperture
Input polarization horizontal
Minimum Power (Average Power)2/(Rep rate X Pulse Width) > 4W2/pulse
Input Pulse Wavelength Range 450 nm – ~4000 nm, spectrometer and crystal dependent
Minimum Pulse width ~ 12 fs
Temporal Range 240 ps
Maximum Time Bandwidth product ~ 50
Data Acquisition
Patents US patent # 7,130,052, 8,068,230
Digitization Resolution 14 – 16 -bit (Spectrometer Dependent)
Minimum Delay Increment 4 fs
Spectrometer Spectral Resolution Minimum 0.04 nm
Spectrometer Spectral Resolution Typical 0.44 nm
Spectrometer Spectral Resolution Maximum ~ 1 nm
Spectral resolution at input wavelength (¡°effective spectral resolution¡±) ~2 x sqrt(2) x spectrometer resolution
Spectral Range Spectrometer Dependent and pulse width dependent, nominally 100 nm – 600 nm per spectrometer
Minimum Integration time (spectrometer dependent) 1 ms¢Ó
Repetition rate (without triggering) 100 Hz – > 1 GHz
Triggered repetition rate < 1 Hz – ~ 1 kHz¢Ô
Intensity Accuracy ~ 2%
Phase Accuracy 0.01 radians 0.01 radians
Spectra required for measurement Number in grid
Acquisition Speed ~130 spectra/second
Maximum Grid Size 1024 x 1024
Maximum Optical Delay acceleration ~12G (estimated)
Maximum speed based on maximum acceleration 21 ns/s (double pass, 1.55 m/s)
Optional Accessories
Software controlled crystal tilt
Direct Drive microstepped, 5 pole stepper motor Yes
Angular resolution < 0.1 degrees
Angular repeatability better than 0.1 degrees
Angular range +/- 30 degrees
Angular tilt scanning for increased phase mathcing bandwidth Yes
Alignment Cameras
Sensor silicon CCD cameras 2
Wavelength range 450 nm – 1000 nm(out to ~1550 nm using 2 photon absorption)
Focal plane of crystal image Yes
Fixed delay beam Yes
USB 2.0 Interface Yes
Frame rate 8-10 Hz
Physical
Dimensions 33 cm x 33 cm x 19 cm
Shipping weight about 40 lbs (18.2 kg)
Power requirements 100 – 230 VAC, 50 – 60 Hz
Electrical Plug style: US NEMA 5-15, change on request
Cover Integrated
Control electronics Integrated
Crystal mounting Removable/replaceable Kinematic Cartridge
Spectrometer Mount Kinematic Removable
Beam splitter Reflective, spatial
Data Analysis
Video FROGscan software Included
Algorithm speed 64 x 64 grid (Core i7, Gen. 7, mobile) > 12,600 iterations per second
Algorithm speed per pixel ~ 20 us
Algorithm type Proprietary PCPG (US patent # 6,219,142, 9,423,307, 10,274,378)
Analysis rate real-time
Update once per frame
Preprocessing background subtraction, smoothing, median filter, adaptive rank filter
Notes
*With the optional Hollow retroreflector
¢ÓMinimum integration time: Flame 1 ms; HR2000+ 1 ms; QEpro 8 ms; Maya Pro 7.2 ms; Ocean FX 10 ¥ìs.
¢Ô At greater than ~50-100 Hz, not every pulse is captured. E.g., pulses are skipped.