UWB Radar Kit ¿ë µðÁöÅ» »ùÇøµ ¿À½Ç·Î½ºÄÚÇÁ
Photo |
Product Name |
Description |
 |
Sampling Oscilloscope GZ10M
|
One channel Digital Sampling Oscilloscope GZ10M is intended for UWB radar measurements in frequency range 10,6 GHz . ¡¤ Economical 10,6 GHz Sampling Oscilloscope ¡¤ Wide range of options ¡¤ UWB Radar Evaluation Kits
Technical Specifications Of GZ10M
Parameter Name |
GZ10M |
Number of channels |
1 |
Bandwidth of channels |
(0,1¡À10,6) GHz |
Dynamic range |
1000 mV |
Sensitivity range |
1 ¡À1000 mV/screen |
CW offset |
(-500 ¡À+ 500) mV |
Noise RMS max |
1,2 mV |
Number of ADC discretes |
12 |
Averaging number (max) |
4096 |
Input impedance of Channel inputs |
50 Ohm |
Time interval resolution |
1,5 ps/point |
Time Window |
100 ns/screen |
Operating mode |
Internal(TDR) |
Operation System |
32 or 64 bit Windows 7/Win10 Operation System |
Power Supply |
DC (10,5–14,5)V |
PRF |
1,0 MHz; 500 kHz; 200 kHz 100 kHz; 50 kHz |
Delay adjustment range |
160 ns (8 steps 20 ns each) |
Maximal Number of points for Time Window |
4096 |
Minimum Requirements for external PC |
USB 2.0 |
Consumption @12 V |
1300 mA @ 12 V |
Dimensions |
(210 x 74 x 220) mm |
Weight, no more |
2,4 kg |
Operating temperature range |
(+5¡À+35)¡ÆC |
Storage temperature |
(-25 ¡À +60)¡ÆC |
Humidity |
95% (at 30¡ÆC) | |
|
|
Photo |
Product Name |
Description |
 |
Sampling Oscilloscope GZ10M2
|
Two channel Digital Sampling Oscilloscope GZ10M2 is intended for UWB radar measurements in frequency range 10,6 GHz . ¡¤ Economical 10,6 GHz Sampling Oscilloscope ¡¤ Wide range of options ¡¤ UWB Radar Evaluation Kits
Technical Specifications Of GZ10M2
Parameter Name |
GZ10M2 |
Number of channels |
2 |
Bandwidth of channels |
(0,1¡À10,6) GHz |
Dynamic range |
1000 mV |
Sensitivity range |
1 ¡À1000 mV/screen |
CW offset |
(-500 ¡À+ 500) mV |
Noise RMS max |
1,2 mV |
Number of ADC discretes |
12 |
Averaging number (max) |
4096 |
Input impedance of Channel inputs |
50 Ohm |
Time interval resolution |
1,5 ps/point |
Time Window |
100 ns/screen |
Operating mode |
Internal(TDR) |
Operation System |
32 or 64 bit Windows 7/Win10 Operation System |
Power Supply |
DC (10,5–14,5)V |
PRF |
1,0 MHz; 500 kHz; 200 kHz 100 kHz; 50 kHz |
Delay adjustment range |
160 ns (8 steps 20 ns each) |
Maximal Number of points for Time Window |
4096 |
Minimum Requirements for external PC |
USB 2.0 |
Consumption @12 V |
1300 mA @ 12 V |
Dimensions |
(210 x 74 x 220) mm |
Weight, no more |
2,5 kg |
Operating temperature range |
(+5¡À+35)¡ÆC |
Storage temperature |
(-25 ¡À +60)¡ÆC |
Humidity |
95% (at 30¡ÆC) | |
|
Photo |
Product Name |
Description |
 |
Sampling Oscilloscope GZ10
|
One or two-channel Digital Sampling Oscilloscope GZ10 is intended for UWB radar measurements in frequency range 10,6 GHz. ¡¤ Economical 10,6 GHz Sampling Oscilloscopes ¡¤ Wide range of options ¡¤ UWB Radar Evaluation Kits
Technical Specifications Of GZ10
Parameter Name |
GZ10 |
Number of channels |
1 or 2 |
Bandwidth of channels |
(0,1¡À10,6) GHz (0,1¡À18) GHz for GZ10/18G |
Dynamic range |
1000 mV |
Sensitivity range |
1 ¡À1000 mV/screen |
CW offset |
(-500 ¡À 500) mV |
Noise RMS max |
1,0 mV 1,3 mV for GZ10/18G |
Number of ADC discretes |
12 |
Averaging number (max) |
4096 |
Input impedance of Channel inputs |
50 Ohm |
Time interval resolution |
1,5 ps/point |
Time Window |
100 ns/screen |
Operating mode |
External/internal(TDR) for GZ10E DC-1,5 GHz (1,0¡À10,0) GHz Internal(TDR) for GZ10T |
Operation System |
32 or 64 bit Windows 7/Win10 Operation System |
Power Supply |
DC (10,5–14,5)V |
Delay adjustment range |
(0¡À40) ns Step 0,01 ns 120 ns for GZ10T 6 steps 20 ns each |
Maximal Number of points for Time Window |
4096 |
Minimum Requirements for external PC |
Processor Pentium, Parallel port (LPT) with EPP mode, USB 2.0/USB 1.1 |
Consumption @12 V |
3000 mA @ 12 V |
Dimensions |
(330 x 65 x 225) mm |
Weight, no more |
4,1 kg |
Operating temperature range |
(+5¡À+35)¡ÆC |
Storage temperature |
(-25 ¡À +60)¡ÆC |
Humidity |
95% (at 30¡ÆC) | |
|
|
Photo |
Product Name |
Description |
 |
Sampling Oscilloscope GZ6E
|
One-channel or two-channel Digital Sampling Oscilloscope GZ6E intended for UWB radar measurements in frequency range up to 6 GHz. ¡¤ Economical 6 GHz Sampling Oscilloscope ¡¤ Base model for UWB Radar Evaluation Kits
Technical Specifications Of GZ6E
Dielectric constants ¥å |
(1–100) |
Parameter Name |
GZ6E |
Number of channels |
1 or 2 |
Bandwidth of channels |
(0,1¡À6) GHz |
Dynamic range |
¡¾500 mV |
Sensitivity range |
10 ¡À1000 mV/screen |
CW offset |
(-500 ¡À 500) mV |
Noise RMS max |
0,85 mV |
Number of ADC discretes |
12 |
Averaging number (max) |
1024 |
Input impedance of Channel inputs |
50 Ohm |
Time interval resolution |
12,5 ps/point (0,0037)m@ ¥å =1,0 |
Time Window |
100 ns/screen (0,15–15)m @ ¥å =1,0 |
Operating mode |
internal(TDR) |
Operation System |
32 or 64 bit Windows 7/Win10 Operation System |
Power Supply |
DC (10,5–14,5)V |
PRF |
250 kHz |
Delay adjustment range |
(0–100) ns (0–15 )m @ ¥å =1,0 |
Maximal Number of points for Time Window |
4096 |
GZ62PC Software |
Control of time window, delay, sensitivity and etc. Life signals on screen Acquire signals and saving Filters: LF, HF Marker measurements Zoom Averaging |
Minimum Requirements for external PC |
Processor Pentium, Parallel port (LPT) with EPP mode, USB 2.0 |
Operating modes |
Real time scanning (Life signals on screen) |
Consumption @12 V |
1300 mA @ 12 V |
Dimensions |
(330 x 65 x 225) mm |
Weight, no more |
3,5 kg |
Operating temperature range |
(+5¡À+40)¡ÆC |
Humidity |
95% (at 30¡ÆC) | |
| |